VERTEBRIS cervical

VERTEBRIS cervical

Innovative Endoscopic Solution for Cervical Spine Surgery

VERTEBRIS Cervical – An advanced full-endoscopic system for minimally invasive cervical spine surgery.

Designed for precision, reduced trauma, and faster recovery, it ensures optimal patient outcomes.

More information

Takes the pressure

The main indications for cervical full-endoscopic operations are "soft" spinal disc herniations with radicular symptoms. Two basic instrument sets are available for use in the cervical spine. They are designed specifically for the special anatomical requirements of an anterior approach and a posterior approach.

The visual quality, and the special design of the instrument sets, allow for a quality of endoscopic surgery equivalent to lumbar procedures. The customized instruments and standardized techniques are important enablers for the success of these innovative surgical methods used on the cervical spine.

Posterior technique

The posterior cervical instrument system includes a specially designed instrument set and a well defined, repeatable, technique for the posterior approach to the cervical spinal canal. The instrumentation includes bone burrs that give the surgeon the ability to perform bone resection under visualization in the area of the foramen, the uncinate process or the posterior edge of the spinal column.

Since the cervical spinal cord cannot be manipulated, the posterior approach is limited to herniations where the main portion of the herniation is localized laterally to the lateral edge of the spinal cord. Under the proper indications, the posterior cervical system provides an excellent endoscopic alternative to open techniques.

Anterior technique

Herniations presenting with their main portion located medially to the lateral edge of the spinal cord are regarded as indications for an anterior approach to the cervical spine. The anterior cervical system includes a custom designed dilator-sleeve system which interfaces with a unique cervical endoscope, as well as specialized instrumentation, to provided excellent access to the posterior disc area. The full-endoscopic anterior cervical approach provides a significantly less traumatic alternative to conventional surgery.

VERTEBRIS cervical posterior

  • High resolution endoscopes with shorter working length for full-endoscopic posterior approach.
  • Optimized ratio of large working channel (3.1mm) to outside diameter (7mm) for minimal invasive access and effective operation.
  • Fluid management optimized by engineered dimensioning of inflow and outflow preventing neural compression by high pressures of the irrigation fluid.
  • Working Sleeves with atraumatic distal design to protect neural structures.
  • Stable grasping forceps and punches with shorter working length and overload protection for posterior approach.
  • Endoscopic high-speed drill system with reusable and disposable tools for mechanical bone and soft tissue resection for cervical foraminotomy.
  • TipControl instruments for 4 MHz radiofrequency coagulation and ablation.

VERTEBRIS cervical anterior

  • Special access system with oval working sleeves to minimize the outer diameter and intradiscal trauma.
  • High resolution endoscopes without integrated working channel for full-endoscopic anterior cervical approach.
  • Endoscope adapter to control the distance between endoscope and working sleeve for more ergonomic work.
  • Fluid management optimized by engineered dimensioning of inflow and outflow preventing neural compression by high pressures of the irrigation fluid.
  • Stable forceps up to 3mm diameter and punches with overload protection for effective soft tissue and bone resection.
  • Endoscopic high-speed burr system with reusable and disposable tools for mechanical bone and soft tissue resection.
  • TipControl instruments for high frequency coagulation.
  • TipControl instruments for 4 MHz radiofrequency coagulation and ablation. 
×
×
Feedback

We use cookies

To optimize our website for you and to continuously improve it, we use cookies. Some cookies are necessary for the operation of the site, while others are used for anonymous statistical purposes or to enhance your user experience. You can decide for yourself which categories you want to allow. Please note that depending on your settings, not all features of the website may be available. Privacy policy

Disclaimer:

The content of this website is intended exclusively for healthcare professionals and is provided for informational purposes only. The information on this website does not replace professional medical advice, diagnosis, or treatment. EMIG GmbH assumes no responsibility for the timeliness, accuracy, or completeness of the information provided. The use of the content on this website is at the user’s own risk. EMIG GmbH reserves the right to modify, supplement, or delete parts of the pages or the entire content without prior notice. Links to external websites are provided solely for user convenience; EMIG GmbH assumes no responsibility for their content.