Radio Surgical Treatments with the radioSURG® 2200

Performed at the MVZ of the Paracelsus Hospital Karlsruhe, Germany

Chief Physician J.H. Reus, MD
Medical Specialist for Plastic and Esthetic Surgery

The Cases

  1. Removal of a Rhinophyma
  2. Basalioma at the Nasal Bridge
  3. Removal of Xanthelasma, Hemangioma and Hair Growth perimamillary
  4. Traumatic Rupture of the Septum Orbitale in Ferio
  5. Removal of pigmented papillomatous Nevus Cell Nevi at the Neck
  6. Anti-Aging-Treatment with the RF-ReFacing® Method

1. Removal of a Rhinophyma

Case Report

The 55-year-old patient had suffered for a longer time from a rhinophyma. Before taking on a new job he thus, wanted it to be removed.

After an infraorbital conduction anaesthesia and regional block anaesthesia with Xylocain 2 % 1:200 000 at the root of the nose and the nose bridge, the surgery area and the complete face are cleaned with Octenisept, a mucosa antiseptic agent.

The Surgical Procedure

With the triangle electrode No. 26 and unit setting CUT 35 watt the basic shape of the nose is reconstructed. To increase the conductivity of the radio waves, the skin is moistened with a wet swab, before it is touched with the activated electrode. This procedure is necessary at the skin surface only.

Download full article

4 April 2025

×
×
Feedback

We use cookies

To optimize our website for you and to continuously improve it, we use cookies. Some cookies are necessary for the operation of the site, while others are used for anonymous statistical purposes or to enhance your user experience. You can decide for yourself which categories you want to allow. Please note that depending on your settings, not all features of the website may be available. Privacy policy

Disclaimer:

The content of this website is intended exclusively for healthcare professionals and is provided for informational purposes only. The information on this website does not replace professional medical advice, diagnosis, or treatment. EMIG GmbH assumes no responsibility for the timeliness, accuracy, or completeness of the information provided. The use of the content on this website is at the user’s own risk. EMIG GmbH reserves the right to modify, supplement, or delete parts of the pages or the entire content without prior notice. Links to external websites are provided solely for user convenience; EMIG GmbH assumes no responsibility for their content.